Voltage stabilizer range MFS-i
  • input Range 145-285V
  • Output range 196-245V
  • Maximum Current 12A
  • Spike & Surge Protection ✓
  • Lightning Protection ✓
  • Overheating Protection ✓
  • Frequency Monitoring ✓
  • Soft Start ✓
  • Zero Voltage Changeover ✓
  • Operating Max Ambient
    85oC
  • High Back Pressure systems, Glass Door Coolers

 

Voltage stabilizer range MFS-IE
  • input Range 75-140V
  • Output range 100-125V
  • Maximum Current 8A
  • Spike & Surge Protection ✓
  • Lightning Protection ✓
  • Overheating Protection ✓
  • Frequency Monitoring ✓
  • Soft Start ✓
  • Zero Voltage Changeover ✓
  • Operating Max Ambient
    85oC
  • High Back Pressure systems, Glass Door Coolers
Voltage stabilizer range MFS-L
  • Input Range 110-285V
  • Output range 196-245V
  • Maximum Current 12A
  • Spike & Surge Protection ✓
  • Lightning Protection ✓
  • Overheating Protection ✓
  • Frequency Monitoring ✓
  • Soft Start ✓
  • Zero Voltage Changeover ✓
  • Operating Max Ambient 85oC
  • High Back Pressure systems, Glass Door Coolers
Voltage stabilizer range MFS-Lw
  • Nominal voltage 110-285V
  • Output range 196-245V
  • Maximum Current 12A
  • Spike & Surge Protection ✓
  • Lightning Protection ✓
  • Overheating Protection ✓
  • Frequency Monitoring ✓
  • Soft Start ✓
  • Zero Voltage Changeover ✓
  • Operating Max Ambient 85oC
  • High Back Pressure systems, Glass Door Coolers
Voltage stabilizer range Wave-i
  • Input Range 145-285V
  • Output range 196-245V
  • Maximum Current 5A
  • Spike & Surge Protection ✓
  • Lightning Protection ✓
  • Overheating Protection ✓
  • Frequency Monitoring ✓
  • Zero Voltage Changeover ✓
  • Operating Max Ambient
    85oC
  • High Back Pressure systems, Glass Door Coolers
Voltage stabilizer range Wave-n
  • Input Range 165-270V
  • Output range 196-245V
  • Maximum Current 5A
  • Spike & Surge Protection ✓
  • Lightning Protection ✓
  • Overheating Protection ✓
  • Frequency Monitoring ✓
  • Zero Voltage Changeover ✓
  • Operating Max Ambient
    85oC
  • High Back Pressure systems, Glass Door Coolers
Voltage stabilizer range Wave-c
  • Input Range 110-285V
  • Output Range 160-245V
  • Maximum Current 5A
  • Spike & Surge Protection ✓
  • Lightning Protection ✓
  • Overheating Protection ✓
  • Frequency Monitoring ✓
  • Zero Voltage Changeover ✓
  • Operating Max Ambient
    55oC
  • Low Back Pressure systems, Chest Freezers/Coolers, Domestic Coolers
Voltage and Frequency Supervisor VFS (Cutter)
  • Nomimal voltage 230/115V
  • Programmable Voltage and Frequency output cutoff
  • Maximum Current 10(6)A
  • Spike & Surge Protection ✓
  • Lightning Protection ✓
  • Overheating Protection ✓
  • Frequency Monitoring ✓
  • Operating Max Ambient
    55oC
  • Any Appliances